T-33 Bilge Pump Installation

on Larina #212—5/2002

Rule 1100 Pump in bilge. Lots of room. Fits easily.

To get all (4) hoses and wires under the engine bed it took some careful cutting.

Hoses: ice box drain; sump; manual bilge pump; and Rule pump

Cover plate with additional backing to cover enlarged hole.

Rule #41 Switch with light.

Upper multiflex hose (rightmost of two) is new with additional hole in engine bed.

New thruhull on transom can be seen left of “L”.

I looped the hose up to the approximate height of the cockpit seat before exiting at the thruhull.